6. If there is no ground effect on the device there is
no interaction on the bar that is indicated in the
figure and “Ground Setting 100% Completed”
expression is displayed. In this case the device is
ready for exploring and you may switch to
explore mode by pressing the “ACCEPT” button.
7. In case there is ground effect on the device an
interaction is observed in the “GROUND ADJUST”
bars that are indicated in the figure. To eliminate
this effect press “-“ button for “-“ effect and
press “+” button for “+” effect. Press “-“ or “+”
buttons until this effect is eliminated and
“Ground Setting 100% Completed” expression is
displayed.
8. After pressing “+” or “-“ buttons lift the search coil 40 cm above ground and press
the “RESET” button and observe the ground effect by holding the search coil 3-5 cm
above ground, if ground effect persists try to eliminate this effect by pressing “+” or
“-“ buttons.
9. If we are not able to eliminate the ground effect decrease the sensitivity level one
step and repeat the above defined operation.
10. After the ground effect is eliminated you may press the “ACCEPT” button and switch
to Explore Mode.